Mon-Fri 09:00-18:00      
Tashkent city, Yunusabad district, st. Okil Ota, 15
Request a call

Shop

Chart monitor OCULUS Vissard RG

Manufacturer: OCULUS, Germany

Description:
The OCULUS Vissard RG is an advanced refraction and vision testing system designed to simulate both daylight and night conditions. Utilizing red-green (anaglyph) technology, it enables naturalistic, binocular vision testing while maintaining realism and high diagnostic accuracy.

Intended Use:
Vissard RG is a powerful tool for clinics, optometrists, and optical stores looking to offer high-quality, realistic vision assessments — from daylight acuity to night-driving simulation — enhancing patient satisfaction and diagnostic precision.

Cloud Hydraulic Stretcher

Standard Features:

  • Frame: Steel frame with multifunctional supports on each corner for accessory attachment.
  • Adjustable Sections: Various configurations for optimal patient positioning and access.
  • Protective Covers: Engineered plastic covers for mechanical parts and flat surfaces.
  • Static Mattress: Removable for easy cleaning and sanitization.
  • Hydraulic Height Adjustment: Operated by pedals on both sides for ease of use.

Dimensions and Specifications:

  • Model Types:
    • Type 1 (Model 7285RT52): 3 sections, width 64 cm, length 195 cm, overall width 82 cm, overall length 209 cm
    • Type 2 (Model 7285RT50): 4 sections, width 64 cm, length 195 cm, overall width 82 cm, overall length 209 cm
    • Type 3 (Model 7285RT60): 2 sections, width 70 cm, length 195 cm, overall width 87 cm, overall length 207.5 cm
    • Type 4 (Model 7285RT61): 4 sections, width 70 cm, length 195 cm, overall width 87 cm, overall length 207.5 cm
  • Maximum Load Capacity: 260 kg
  • Safe Working Load: 320 kg
  • Height Adjustment Range: 550 mm to 850 mm

Computerized contactless tonometer ST-800 Topcon

Topcon CT-800, a non-contact computerized tonometer for measuring intraocular pressure. Clear 8.5-inch touchscreen to control all functions with one touch. The base moves more smoothly due to a 23% reduction in weight compared to previous tonometer models; an improved joystick simplifies the operation of the CT-800. A soft jet of air ensures the accuracy of […]

Computerized Pentacam AXL Corneotopograph

The device offers various measurement options:

🔹 Keratometry measurements using Pentacam.
The gold standard in anterior segment tomography, Pentacam performs a comprehensive examination of the anterior segment, including measuring the anterior and posterior surfaces of the cornea, the real total optical strength of the cornea (TCRP map), pachymetry and many other parameters.

🔹 Measurement of the axial length of the eye
The noninvasive optical biometrics method based on the technology of partial coherent interferometry allows you to quickly obtain all the necessary data for the calculation of IOL.

🔹 Combined measurement
Both measurements: keratometry and PZO of the eye, are made along the same axis, taking into account the micro-movements of the eye, allowing you to get the most reliable data.

🔹 Modern IOL calculator
Pentacam AXL allows you to get reliable data and make calculations even in the most difficult cases, for example, after LASIK, PRK, RK. Special formulas will help in any case.

Contactless CT-1P tonometer from TOPCON

Medical equipment in Tashkent is supplied from trusted manufacturers. The non-contact tonometer of this modification has the following advantages:

– automated control via touch screen;
– readings are obtained quickly and reliably;
– the equipment is compact and flexible;
– air jet is soft;
– calculation of the corrected IOP value.

Corneal topograph keratograph 5M Oculus

Advantages of the 5M Keratograph:
<

    • Professional selection of contact lenses for quick and easy selection, the program selects the contact lens from the integrated database that is necessary for this particular patient, and also simulates a fluorescent image (imitation) to visualize the lens fit on the cornea.
    • TF-Scan Keratograph 5M allows for a more detailed diagnosis of pathologies associated with the formation and distribution of tear fluid. Thus, the assessment of the level of tear production can be estimated by the height of the lacrimal meniscus.

<

    • R-Scan automatic classification of conjunctival redness Scan is the first software module that not only documents the level of redness of the patient’s eyes, but also automatically classifies it.
    • Meibography of the upper and lower eyelids the device automatically recognizes the boundaries of the eyelid and adjusts the contrast for the clearest possible visualization.

</

Cornealtopograph Pentacam® AXL Wave

Manufacturer: OCULUS, Germany

Description:
The OCULUS Pentacam® AXL Wave combines five core technologies in one device: Scheimpflug tomography, optical biometry, wavefront aberrometry, retroillumination, and objective refraction. It provides a complete diagnostic picture of the anterior segment, making it ideal for refractive and cataract surgery planning and follow-up.

Application:
The Pentacam® AXL Wave is ideal for modern ophthalmic practices requiring high-level diagnostics for surgical planning and postoperative management. It supports accurate IOL calculations, early detection of corneal disorders, and evaluation of visual quality.

Corneotopographer Pentacam® HR

Manufacturer: OCULUS, Germany
Description:
The OCULUS Pentacam® HR is an enhanced version of the classic Pentacam® system, featuring a high-resolution digital Scheimpflug camera. It provides fast, precise imaging of the entire anterior segment, including the cornea, iris, lens, and anterior chamber. Its high detail level makes it ideal for diagnosing keratoconus, evaluating anterior chamber depth, and planning IOL implantation.

Application:
The Pentacam® HR is ideal for ophthalmology clinics, diagnostic centers, and refractive surgery practices. It is essential for evaluating patients with suspected keratoconus, planning cataract or laser surgeries, and performing full anterior segment assessments.

CS-700 workplace included

Included:

    • Table with 90 degree rotation, convenient access
    • The table is made of the highest quality materials
    • A simple mobile and movable table for placing a refractometer and an ophthalmotonometer.
    • It is qualitatively made, ranging from the thickness of the sheet metal to the mounting of the plug and the choice of screws.

</

CV-5000 Pro Topcon Foroptor

This device is used to measure the refractive power of the eye and to check binocular functionality. The compact design of the camera lens makes it possible to see the patient’s face. The distance visual acuity test table can be controlled by the 1 Dial controller. PD (Interpupillary distance) and alignment of the anterior chamber […]

Dental Unit KLT-6220

Doctor’s block
— lower giving of tools;
— touch control panel;
– gun water / air / spray;
— 3 tubing connector M4;
– negatoscope;
– silicone autoclavable mat.

Digital (electronic) foroptor VT-700

• Wide range of measurements
• Synchronized cross-cylinders
• Protection of optics against pollution
• Availability of auxiliary lenses
• Quick and accurate results
• Easy management and clear scales
• Sphere: -29.00 D ~ + 26.75 D (step: 0.12/0.25/0.5/1/2/3 D)
• Cylinder: 0.00 D ~ 8.75 D (step: 0.25/0.5/1/2/3 D)
• Cylinder axis: 0 ~ 180 ° (spacing: 1 / 5 / 15 / 30 / 45 °)
• Inter-transparent distance PD: long range: 48 ~ 80 mm, close range: 45 ~ 75 mm (spacing: 0.5/1.0 mm)
• Working distance: 35 ~ 70 cm (step: 5 cm)
• Prism: 0 ~ 20 D (step: 0.1/0.2/0.5/1/2 D)
• Cross cylinder: Jackson cross cylinder ± 0.25D and ± 0.5D, double cross cylinder ± 0.25D
• Ophthalmoscope: + 1,5D + 2,0D (measuring distance 67 cm, 50 cm)
• Switch with point: Ø 1 mm
• Madoka lenses: right (horizontal), left (vertical)
• Red-green filter: right red, left green
• Polarization filter: right eye (135 °, 45 °), left eye (45 °, 135 °)
• Dividing prism: right eye (6 ∆BI), left eye (10 ∆BI)
• Solid suprachiasmatic cylinder: 0.50D, 90 ° axis fixation
• Display: 9.7 inches
• Article size: main engine housing – 362 * 83 * 299 mm, keyboard – 215 * 230 * 226 mm, junction box – 266 * 72 * 240 mm
• Product weight: main engine housing – 3.5 kg, keyboard – 1.5 kg, junction box – 1.3 kg
• Current consumption: 90 VA
• Power supply: 100 ~ 240 V, 50/60 Hz
• Quality: Grade 1

Digital sign projector C901

Liquid crystal table for demonstration of optotypes to test visual acuity. Includes a set of tables for checking visual acuity in both adults and children. It is possible to check binocular and color vision. And also, it has tests for contrast sensitivity and tables for checking vision in macular degeneration